P&ID QC · Upgrade, priced separately

Small errors on a P&ID find expensive ways to become big problems.

A drawing that reads cleanly can still carry mismatches an engineer would only catch by re-tracing it by hand. P&ID QC checks your extraction against the drawing itself — starting with line numbers — and flags what doesn't match, what's missing, and what it can't confirm.

Works on clean, CAD-native P&IDs today. Scanned and flattened drawings aren't yet supported for this check.

Request beta access → See how it works
🔎

How this is different: P&ID QC never changes a valve assignment on its own. Every result is a flag for your review; the final engineering decision stays with you.

// What it checks

One question, asked for every valve on the drawing

Does the line number assigned to this valve match what the drawing itself shows for it — not just the nearest text label?

Contradictions

The assigned line doesn't match — flagged as a likely misread, along with the line the drawing actually shows.

Recoverable blanks

A line number was left blank — P&ID QC can suggest one from what the drawing shows for that valve.

Self-conflicts

Two valves that share the same line run were assigned different line numbers — worth a second look.


// Verdicts

Five honest outcomes — not a pass/fail

P&ID QC doesn't reduce a drawing to a single score. Every valve gets one of five verdicts, so you know exactly where to spend your review time.

Supported

The assigned line matches what the drawing shows.

Contradicted

It doesn't match — likely a misread.

Recoverable

Blank line, but one can be suggested.

Plausible

Consistent, but confidence is lower.

Unvalidated

Can't be checked — left honest, not guessed.

How to use P&ID QC output

Think of it as a second, independent check against your extraction. It reduces how much of the drawing you have to manually re-trace, but it doesn't replace your review. Every contradiction, recovery, and conflict is a flag for a qualified engineer to confirm — PID Intelligence does not change a valve assignment on its own.


// Process

How it fits into your workflow

An upgrade on top of P&ID Extraction, with its own plan and pricing — no separate tool to open.

01

Upload

Upload your P&ID and run P&ID Extraction as usual — valve schedule, line numbers, the full output.

02

Validate

P&ID QC checks every valve's assigned line as part of that same extraction — no separate tool to open.

03

Export

Work through anything flagged, then export your results — ready for your records.


// One of several checks

P&ID QC is a family of checks, not one score

Line-to-drawing validation — the check on this page — is the first available today. It's part of a broader set of checks under the PID Intelligence QC name, including checks that reconcile a drawing against an official line list or tag register. More become available as your plan supports them.


// Sample output

What a validation run looks like

Each row is one valve. P&ID QC either confirms the assigned line, flags what doesn't match, or is honest that it can't check that one.

TagAssigned lineVerdictDrawing showsConfidence
FV-1019001-8-UA-A1A01-0010Supported9001-8-UA-A1A01-0010High
MV-12472101-CS-150Contradicted2104-CS-150High
BV-0440Recoverable1800-CS-150Medium
CV-05121800-CS-150Supported1800-CS-150High
PSV-02103050-SS-300Unvalidated

Sample only — illustrative of verdict behaviour. Actual results depend on drawing quality and how much of the drawing can be resolved.


// Common questions

Questions about P&ID QC

Does this cost extra?

Yes — P&ID QC is its own plan, priced separately from P&ID Extraction. It's not included automatically with an extraction plan.

What does it actually check?

Whether the line number assigned to each valve matches what the drawing itself shows for that valve. It doesn't check spec codes, NPS, valve type, or drawing conventions — those live in your extraction output.

Can it change my extraction results?

No. P&ID QC never changes a valve assignment on its own. Every contradiction, recoverable blank, or conflict is presented as a flag for you to review and decide on — the final engineering decision stays with you.

Does it work on every drawing?

Right now, P&ID QC works on clean, CAD-native P&IDs. Scanned or flattened drawings aren't supported for this check yet — those valves show as unconfirmed rather than a guess.

How is my drawing data handled?

See our Privacy Policy for full details on how your data is processed and retained.


// Pricing Beta pricing — subject to change

Quality Control

One package that includes every validation check — no separate subscription.

Starter
$139/mo CAD

For smaller firms or project-based work — matches P&ID Extraction Starter volume.

  • 20 drawings/mo
  • Checks every valve's assigned line against the drawing
  • Flags contradictions, recoverable blanks, and self-conflicts
  • Never changes an assignment on its own — review-only
Request early access →

Full plan pricing on the Pricing page →

Try P&ID QC on your next extraction

No separate tool to open — it runs as part of the extraction itself.

Request beta access →